By Michael Achkar | Last updated:
A concrete slab is not as dry as it looks. Ground moisture moves up through it as vapor, and in a metal building that moisture can reach flooring, stored goods and the air that your wall and roof vapor retarder is working to keep dry. A sheet of plastic under the slab, and in some buildings a layer of foam, is the cheapest time to deal with it. This guide explains what goes under a slab, what the standards say, and what to specify.
Key Takeaways
- An under slab vapor retarder slows moisture moving from the ground into the concrete.
- ASTM E1745 sorts these membranes into Class A, B and C, and Class A is the toughest.
- Industry guidance recommends a minimum thickness of 10 mils and a sealed installation.
- Where the slab will get a moisture sensitive floor, ACI guidance places the concrete directly on the retarder.
- Foam under the slab is a thermal break. It is a separate decision from the vapor retarder.
- Final specifications belong to your engineer of record and flooring manufacturer.
Why It Matters
A properly selected and installed under slab vapor retarder is the first line of defense against water vapor and soil gas migration, according to GBD Magazine, and once the concrete is poured, fixing a problem becomes costly and slow. That is why this is worth getting right before the pour.
Vapor Retarder, Vapor Barrier and What the Standards Say
The two terms are often mixed up. ASTM E1745 is the standard specification for plastic water vapor retarders used in contact with soil or granular fill under concrete slabs. It defines three classes, A, B and C, based on puncture resistance, tensile strength and water vapor permeance. A Class A material is more resistant to tearing and punctures than Class B and C, as noted in a continuing education course on under slab barriers.
The Concrete in Practice publication CIP 29 recommends a minimum thickness of 10 mils for reduced vapor transmission and for the durability needed during construction, and recommends installing the retarder in accordance with ASTM E1643. It also says older materials once common have been replaced by stronger, less permeable products that conform to ASTM E1745. A contractor article in For Construction Pros adds that products made with recycled content can deteriorate in the ground and may not hold their permeance, and that heavier Class A membranes are worth considering if you will use pumps or laser screeds over the sheet.
A caution on thickness. GBD Magazine quotes an industry expert that more mils does not always mean better performance, and that a single extruded film made from recycled content can perform worse than a thinner film made from virgin resin. Choose by the tested class and the ASTM data, not by the mil number alone.
Where to Put It
ACI Committee 302 recommends placing the concrete directly on top of the vapor retarder when the slab will receive a moisture sensitive floor covering, according to CIP 29. The AECOM construction bulletin on slab vapor retarders points to ACI 302.1R, ACI 302.2R and ACI 360R as the references for location, and lists moisture sensitive floors such as vinyl tile, sheet goods, epoxy and carpet as the case where the retarder goes directly under the slab.
If there is no moisture sensitive floor, the choice of placement has more room for judgment, and your engineer will decide based on the project.
Install It Right
- Lap the seams as the manufacturer directs and tape them with the manufacturer's tape.
- Seal around pipes and penetrations with the manufacturer's mastic or boot, as shown in the AECOM bulletin.
- Protect the sheet from punctures during rebar, forming and pouring work.
- Check the sheet before the pour and repair any tears.
Foam Under the Slab
Under slab insulation is not the same as a vapor retarder. The Waterproof Magazine article on under slab barriers notes that a thermal break beneath the slab can eliminate condensation on a cold slab surface, which is why some products combine a barrier with a layer of foam. For a heated building, check your energy code, because slab edge or under slab insulation can be a requirement depending on the climate zone and how the building is used. Your wall insulation and vapor retarder at the slab edge should also be coordinated. See our guides to wall insulation and the vapor retarders used on Butler buildings.
Residential Code as a Reference Point
The 2021 International Residential Code upgraded its under slab requirement from a 6 mil retarder to a 10 mil retarder that conforms to ASTM E1745 Class A, according to GBD Magazine. That is a residential code, and a commercial or industrial building follows the commercial code and its specifications, but it shows where the industry baseline has moved.
Checklist for Your Specification
- Which ASTM E1745 class and minimum thickness does the engineer require?
- Will the slab get a moisture sensitive floor covering?
- Is the retarder directly under the concrete or under a granular layer?
- Does the heated slab or the climate zone call for foam under the slab or at the edge?
- Who is responsible for sealing penetrations and inspecting before the pour?
FAQ
Q: Do I need a vapor retarder under every metal building slab?
It depends on the floor use and the engineer's design, but it is a low cost step compared with fixing moisture problems after the pour.
Q: Is thicker plastic always better?
No. Tested class and material quality matter more than thickness alone.
Q: Does the wall vapor retarder protect against ground moisture?
No. The wall and roof retarder controls moisture moving through the envelope. Ground moisture needs its own control under the slab.
Planning a New Building?
We can help you coordinate the Butler wall, roof and insulation parts with the rest of the envelope. See our new construction support or request a same day quote.
Sources
- GBD Magazine: Residential Concrete Slabs, Under Slab Vapor Retarders
- GBD Magazine: Guide to Vapor Barriers
- Concrete in Practice, CIP 29: Vapor Retarders Under Slabs on Grade
- For Construction Pros: Selecting and Installing Vapor Retarders under Concrete Floors
- AECOM Hunt Quality Bulletin: Minimum Slab on Grade Vapor Barrier
- Vapor Barriers under Concrete Slabs, How to Select and Locate
- Waterproof Magazine: Vapor Barriers Under Concrete Slabs



