Butler Building QuoteOEM Part/Panel Quote
Make an AppointmentNationwide Job-Site Delivery

Request Butler Metal Building Parts

Tell us what parts you need and where they're going, and our team will confirm availability, pricing, and delivery timing. Every request is reviewed against genuine factory-spec Butler parts.

Thank you! Your request has been submitted — we'll be in touch shortly.

🔒 Your information is secure and never shared. No spam — ever.

Request a New Butler Building Quote

Tell us about your project and we'll put together accurate pricing on a genuine factory-spec Butler building. Every quote is engineer-reviewed and tailored to your building type, size, and timeline.

Thank you! Your request has been submitted — we'll be in touch shortly.

🔒 Your information is secure and never shared. No spam — ever.

Weathered structural steel roof framework and purlins against trees and a bright sky

Thermal Bridging and Continuous Insulation in Metal Buildings

Published November 26, 2026

By Michael Achkar  |  Last updated:

A metal building is mostly steel, and steel moves heat very well. Every purlin, girt, clip and fastener that passes through the insulation layer is a shortcut for heat, which is why the R value printed on the insulation is rarely the performance you actually get. This is called thermal bridging, and it is the main reason energy codes ask for specific insulation assemblies and not just a thick blanket. Here is where the bridges are in a metal building and what the common fixes do.

Key Takeaways

  • Thermal bridges are conductive paths that let heat go around the insulation.
  • In a metal building the biggest ones are purlins, girts, clips and the compressed insulation where the panel is fastened down.
  • Thermal spacer blocks, filled cavity and liner systems, and continuous insulation each reduce the effect in a different way.
  • Insulated metal panels are not considered continuous insulation under ASHRAE 90.1, but the code does not require continuous insulation to comply.

What a Thermal Bridge Is

Building Enclosure describes thermal bridges as most often caused by structural elements that carry loads from the envelope to the building structure. They lead to buildings that do not heat or cool efficiently and have higher utility bills, and they can also cause condensation when humid indoor air meets a cold surface. The ASHRAE Journal notes that Standard 90.1 2022 added new provisions for thermal bridging, and that it covers three types: clear field, linear and point thermal bridges.

Where the Bridges Are in a Metal Building

  • Purlins and girts. The steel members the panels attach to sit directly in the insulation path.
  • Compressed insulation. The National Insulation Association explains that for screw down roofs, the compression of the insulation between the purlins and the roof sheet has a major impact on thermal performance.
  • Fasteners and clips. The same source lists thermal short circuits at fasteners among the factors that make metal building insulation more complex than it looks.

The Metal Building Systems design reference quantifies one case. Insulation with an R value of 10 would lose about 25 percent of its efficiency in this kind of installation, while insulation rated R19 would lose about 42 percent. The thicker the blanket, the more it loses at the purlin, because the heat loss through the steel stays nearly constant.

Common Fixes

ApproachHow it reduces bridgingNotes
Thermal spacer blocksA strip of foam above the purlin stops the panel from crushing the insulation against the steelThe Construction Specifier describes these blocks as adding insulation value where the blanket is compressed between purlin and roof sheet. Code tables set a minimum block size for the assembly
Filled cavity systemA second layer fills the space between the purlins, with the bridging purlin still presentOften uses long tab banding and a thermal block above the purlin
Liner systemA continuous fabric and banding hold two layers of fiberglass, with a block above the purlinUsually a private label system that must meet ASHRAE requirements to be called a liner system
Continuous insulationInsulation that runs across the structure without thermal bridges other than fasteners and service openingsApplied inside, outside or integral to the surface

The Owens Corning compliance guide assumes at least R3 thermal spacer blocks for single layer roofs, R5 blocks for filled cavity systems and R3 for liner systems. Always check the block size your chosen U factor was calculated with.

What Counts as Continuous Insulation

ASHRAE 90.1 defines continuous insulation as insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. The ASHRAE 90.1 2016 version, as quoted by CENTRIA, adds that it is uncompressed.

Two points from the same CENTRIA analysis are worth knowing. First, insulated metal panels are not considered continuous insulation, because ASHRAE treats them as a building material. Second, continuous insulation is not a code requirement. Compliance can be shown through other paths, including a U factor for the full assembly. Standard 90.1 2022 also added a definition for insulated metal panels and specific requirements for them in several sections.

The National Insulation Association separates high R value metal building roof systems into two groups, filled cavity fiberglass and rigid continuous foam. Both groups cover walls as well.

Thermal Bridging and Condensation

A bridge is also a cold spot. Moisture in warm indoor air can condense on cold steel, so reducing the bridge helps control condensation as well as energy loss. The Metal Building Manufacturers Association guide, as summarized by Metal Construction News, says correctly installed insulation is an effective thermal break that isolates cold surfaces by warming them. For the moisture side of the story, see our vapor retarder guide.

How to Choose

  • Start from your code target and the published U factor for the full assembly, not the blanket R value. Our guide to U value vs R value explains why.
  • Match the system to the framing. Purlin spacing and clip height decide which assemblies work.
  • Keep the thermal blocks, banding and fasteners in the order. They are part of the number.
  • If you want a continuous layer, ask whether the panel or board is counted as continuous insulation in your code path.

To see how the pieces fit together, read how to choose an insulation system for a new metal building.

FAQ

Q: Do thermal blocks really matter?

Yes. Code tables for metal building roofs set the block size as a condition of the assembly. Leave it out and the listed U factor does not apply.

Q: Are insulated metal panels continuous insulation?

Not under the ASHRAE 90.1 definition used in the CENTRIA analysis, but they can still be used to comply with the code.

Q: Does more insulation fix thermal bridging?

Not on its own. A thicker blanket loses a larger share of its rating at the purlin. Addressing the bridge matters more.

Talk to Us About Your Roof or Wall Assembly

Tell us the framing, panel and climate zone and we will help you find the right insulation parts. Request a same day quote or see our roof insulation and wall insulation pages.